Skip to main navigation Skip to search Skip to main content

A model-based radiostereometric analysis (RSA) randomized control trial evaluating the stability of the cementless Taperloc hip stem: the TapHip study 2-year follow-up RSA and PROMs results

  • Ruben Y. Kok
  • , Lennard A. Koster
  • , Bart L. Kaptein
  • , Marta Fiocco
  • , Stefan B. Keizer

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Background and purpose – The Taperloc Complete hip is the successor of the Taperloc hip, aiming to increase range of motion and optimizing femoral fit with intermediate stem sizes. We evaluated whether these design changes affect fixation, and this RSA study compares 2-year migration. Patients and methods – In this prospective, multi-arm study, 100 patients were randomized to cementless total hip arthroplasty (THA) with Taperloc Complete full profile (TCFP), Taperloc Complete reduced distal (TCRD), Taperloc full profile (TFP), or Taperloc reduced distal (TRD). Migration was measured with model-based RSA postoperatively, and after 3, 12, and 24 months. Results – Results based on mixed-model analysis on 2-year postoperative RSA data from 74 patients showed similar subsidence (mm) in the first 3 months (mean [95% CI] TCFP 0.44 [0.20–0.69], TCRD 0.91 [0.40–1.42], TFP 0.71 [0.22–1.19], TRD 1.25 [0.58–1.91]) and stabilization after-wards. The TCFP showed statistically significantly less retroversion (°) at 2-year postoperatively compared with TFP and TCRD (mean [95% CI] TCFP: –0.13 [–0.64 to 0.38], TCRD: 0.84 [0.35–1.33], TFP: 0.56 [0.12–1.00], TRD: 0.37 [–0.35 to 1.09]). Interpretation – As expected in successful cementless THA, RSA shows stabilization after initial subsidence. Based on these results the Taperloc Complete stem is expected to have similar long-term fixation to the Taperloc stems. The reduced distal groups have larger, but statistically non-significant, initial migration compared with the TCFP group, which could be due to implantation in Dorr B, C femur types. It may be important to consider the femur shape for choosing a full profile or reduced distal stem to minimize migration.

Original languageEnglish
Pages (from-to)212-221
Number of pages10
JournalActa Orthopaedica
Volume93
DOIs
Publication statusPublished - 3 Jan 2022
Externally publishedYes

Keywords

  • Arthroplasty, Replacement, Hip/adverse effects
  • Femur/surgery
  • Follow-Up Studies
  • Hip Prosthesis
  • Humans
  • Prospective Studies
  • Prosthesis Design
  • Prosthesis Failure
  • Radiostereometric Analysis

Fingerprint

Dive into the research topics of 'A model-based radiostereometric analysis (RSA) randomized control trial evaluating the stability of the cementless Taperloc hip stem: the TapHip study 2-year follow-up RSA and PROMs results'. Together they form a unique fingerprint.

Cite this