Skip to main navigation Skip to search Skip to main content

LUMiC Endoprosthetic Reconstruction of Periacetabular Tumor Defects: A Multicenter Follow-up Study

  • The LUMiC® Study Group

Research output: Contribution to journalArticlepeer-review

9 Citations (Scopus)

Abstract

Background: We previously reported promising early results for periacetabular tumor reconstructions using the LUMiC prosthesis. The current study evaluates mid-term complications, revision rates, cumulative incidence of implant revision, and risk factors for complications in a multicenter cohort. Methods: We assessed patients in whom a tumor defect after type P1b+2, P2, P2+3, or P1b+2+3 internal hemipelvectomy was reconstructed with a LUMiC prosthesis during the period of 2008 to 2022. Complications were reported according to the Henderson classification. Competing risks models were used to estimate the cumulative incidence of implant revision for mechanical and nonmechanical reasons, and reoperations for any complication. Cox models were used to study the effect of risk factors on dislocation and infection. Results: One hundred and sixty-six patients (median follow-up, 4.2 years [interquartile range, 2.6 to 7.6 years]) were included. A total of 114 (69%) were treated for a primary malignant tumor, 46 (28%) for metastatic carcinoma, 5 (3%) for a benign aggressive lesion, and 1 (1%) for another reason. One hundred and sixty-five reoperations were performed in 82 (49%) of the patients; 104 (63%) of the reoperations were within 6 months. Thirty-two (19%) of 166 implants were revised: 13 (8%) for mechanical reasons, mainly dislocation (n = 5, 3%), and 19 (11%) for nonmechanical reasons, mainly periprosthetic joint infection (PJI) (n = 15, 9%). The cumulative incidences of revision for mechanical reasons and PJI (Henderson 1 to 4) at 2, 5, and 10 years were 11% (95% confidence interval [CI], 7% to 17%), 18% (12% to 25%), and 24% (16% to 33%), respectively. Previous surgery at the same site was associated with an increased dislocation risk (cause-specific hazard ratio [HRCS], 3.0 [95% CI, 1.5 to 6.4]; p < 0.01), and resections involving the P3 region were associated with an increased infection risk (HRCS, 2.5 [95% CI, 1.4 to 4.7]; p < 0.01). Conclusions: Despite a substantial reoperation risk, the LUMiC prosthesis demonstrated its durability in the mid-term, with a low mechanical revision rate and most patients retaining their primary implant. Most complications occur in the first postoperative months. Patients with previous surgery at the same site had an increased dislocation risk and might benefit from more conservative rehabilitation and aftercare. Measures should be aimed at reducing the PJI risk, especially in resections involving the P3 region.

Original languageEnglish
Pages (from-to)1309-1316
Number of pages8
JournalJournal of Bone and Joint Surgery - American Volume
Volume106
Issue number14
DOIs
Publication statusPublished - 17 Jul 2024

Fingerprint

Dive into the research topics of 'LUMiC Endoprosthetic Reconstruction of Periacetabular Tumor Defects: A Multicenter Follow-up Study'. Together they form a unique fingerprint.

Cite this