Prenatal prediction of pulmonary hypoplasia: Clinical, biometric, and Doppler velocity correlates

Jacqueline A.M. Laudy, Dick Tibboel, Simon G.F. Robben, Ronald R. De Krijger, Maria A.J. De Ridder, Juriy W. Wladimiroff

Research output: Contribution to journalArticlepeer-review

81 Citations (Scopus)

Abstract

Objectives. To determine the value of pulmonary artery Doppler velocimetry relative to fetal biometric indices and clinical correlates in the prenatal prediction of lethal lung hypoplasia (LH) in prolonged (>1 week) oligohydramnios. Methods. Forty-two singleton pregnancies with oligohydramnios associated with premature rupture of membranes ([PROM]; n = 31) or bilateral renal pathology (n = 11) were examined using color-coded Doppler ultrasound in a cross-sectional study design. Mean gestational age was 28.0 ± 4.3 weeks (range: 20-36 weeks). Thoracic, cardiac, and abdominal circumference and the largest vertical amniotic fluid pocket were measured. Pulsed Doppler measurements of the arterial pulmonary branches were made at the level of the cardiac 4-chamber view. Diagnosis of LH was based on clinical, radiologic, and pathologic criteria. Clinicians were blinded to the prenatal measurements. Results. The prevalence of lethal LH was 43%. In the PROM subset, combination of onset of PROM at ≤20 weeks, duration of oligohydramnios at ≤8 weeks, and degree of oligohydramnios at ≤1 cm presented the highest clinical prediction rate for lethal LH. For both the total group and the PROM subset, the highest prediction rate for lethal LH was presented by thoracic circumference/abdominal circumference ratio, peak systolic velocity in the proximal branch, and time-averaged and end-diastolic velocity in the middle branch of the pulmonary artery. In the PROM subset, the combination of all 3 clinical, biometric, and Doppler parameters revealed the most favorable combination to predict lethal LH (positive predictive value: 100%; accuracy: 93%; and sensitivity: 71%). Conclusion. Doppler velocimetry may detect changes in pulmonary artery waveforms in the presence of LH but fails to be the ultimate test for the prenatal prediction of lethal LH. The best prediction can be achieved by combining clinical, biometric, and Doppler parameters.

Original languageEnglish
Pages (from-to)250-258
Number of pages9
JournalPediatrics
Volume109
Issue number2 I
DOIs
Publication statusPublished - 2002
Externally publishedYes

Keywords

  • Doppler velocimetry
  • Human fetus
  • Oligohydramnios
  • Premature rupture of membranes
  • Pulmonary circulation
  • Pulmonary hypoplasia

Fingerprint

Dive into the research topics of 'Prenatal prediction of pulmonary hypoplasia: Clinical, biometric, and Doppler velocity correlates'. Together they form a unique fingerprint.

Cite this