Doorgaan naar hoofdnavigatie Doorgaan naar zoeken Ga verder naar hoofdinhoud

Multicenter validation of secondary hemophagocytic lymphohistiocytosis diagnostic criteria

  • Gunnar Lachmann
  • , Patrick Heeren
  • , Friederike S. Schuster
  • , Peter Nyvlt
  • , Claudia Spies
  • , Insa Feinkohl
  • , Thomas Schenk
  • , Wafa Ammouri
  • , France Debaugnies
  • , Lionel Galicier
  • , Yuan Jia
  • , Nikhil Meena
  • , Carole Nagant
  • , Olaf Neth
  • , Stefan Nierkens
  • , Juan San Martin
  • , Hao Wei Sun
  • , Yini Wang
  • , Zhao Wang
  • , Jae Ho Yoon
  • Frank M. Brunkhorst, Paul La Rosée, Gritta Janka, Cornelia Lachmann

Onderzoeksoutput: Bijdrage aan tijdschriftArtikelpeer review

22 Citaten (Scopus)

Samenvatting

Background:: Five fulfilled hemophagocytic lymphohistiocytosis (HLH)-2004 criteria, and the HScore are widely used and recommended by international expert consensus to diagnose secondary HLH. Both diagnostic scores have never been validated in heterogeneous patient cohorts of secondary HLH patients. We aimed to systematically optimize and validate diagnostic criteria of secondary HLH using a multicenter approach. Methods:: We developed optimized criteria in our cohort of critically ill patients as a first step. We next validated these new criteria together with the original and modified HLH-2004 criteria as well as the HScore using original data of 13 published cohorts, which were identified by a systematic literature search. Results:: The best performing HLH diagnostic criteria sets over all 13 validation cohorts were the original HLH-2004 criteria with a decreased cut-off (cut-off 4, mean sensitivity 86.5%, mean specificity 86.1%), followed by the revised HLH-2004 criteria (natural killer cell activity removed; cut-off 4, mean sensitivity 83.8%, mean specificity 87.8%) and the HScore (cut-off 169, mean sensitivity 82.4%, mean specificity 87.6%). Our newly developed HLH diagnostic criteria showed inferior performance. Ferritin ≥500 µg/L had 94.0% mean sensitivity over all cohorts. Conclusions:: In this first multicenter validation study, four fulfilled HLH-2004 criteria and an HScore of 169 were suitable to diagnose secondary HLH, which will lead to rapid diagnosis and improved patient outcomes. Ferritin proved as a reliable HLH screening marker. Our results should be taken into account in clinical recommendations and in designing new studies.

Originele taal-2Engels
Pagina's (van-tot)312-327
Aantal pagina's16
TijdschriftJournal of Internal Medicine
Volume297
Nummer van het tijdschrift3
DOI's
StatusGepubliceerd - mrt. 2025

Vingerafdruk

Duik in de onderzoeksthema's van 'Multicenter validation of secondary hemophagocytic lymphohistiocytosis diagnostic criteria'. Samen vormen ze een unieke vingerafdruk.

Citeer dit