Quantification of HIV protease inhibitors and non-nucleoside reverse transcriptase inhibitors in peripheral blood mononuclear cell lysate using liquid chromatography coupled with tandem mass spectrometry

  • R. ter Heine
  • , M. Davids
  • , H. Rosing
  • , E. C.M. van Gorp
  • , J. W. Mulder
  • , Y. T. van der Heide
  • , J. H. Beijnen
  • , A. D.R. Huitema

Onderzoeksoutput: Bijdrage aan tijdschriftArtikelpeer review

32 Citaten (Scopus)

Samenvatting

For pharmacokinetic monitoring, measurement of antiretroviral agents in plasma is the gold standard. However, human immunodeficiency virus protease inhibitors (PIs) or non-nucleoside reverse transcriptase inhibitors (NNRTIs) exert their action within the infected cell. Cell-associated concentrations may therefore more adequately reflect therapy outcome. Therefore, for the quantification of nine PIs (amprenavir, atazanavir, darunavir, indinavir, lopinavir, nelfinavir, ritonavir, saquinavir and tipranavir), 1 active PI metabolite (nelfinavir M8) and 2 NNRTIs (efavirenz and nevirapine) in lysate of peripheral blood mononuclear cells (PBMCs) an assay was developed and validated, using liquid chromatography coupled with tandem mass spectrometry. Analytes were extracted from a PBMC pellet by means of a one-step extraction with 50% methanol containing the internal standards D6-indinavir, D5-saquinavir, 13C6-efavirenz and dibenzepine. Chromatographic separation was performed on a reversed phase C18 column (150 mm × 2.0 mm, particle size 5 μm) with a quick stepwise gradient using an acetate buffer (pH 5) and methanol, at a flow rate of 0.25 mL/min. The analytical run time was 10 min. The triple quadrupole mass spectrometer was operated in the positive ion-mode and multiple reaction monitoring was used for drug quantification. The method was validated over a range of 1-500 ng/mL in PBMC lysate for all analytes. The method was proven to be specific, accurate, precise and robust. The mean precision and accuracy was less than ±12% at all concentration levels. Using the developed assay and a previously developed assay for these analytes in plasma, the relationship between plasma and intracellular pharmacokinetics and their relationship with therapy outcome can now be determined.

Originele taal-2Engels
Pagina's (van-tot)575-580
Aantal pagina's6
TijdschriftJournal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
Volume877
Nummer van het tijdschrift5-6
DOI's
StatusGepubliceerd - 15 feb. 2009
Extern gepubliceerdJa

Vingerafdruk

Duik in de onderzoeksthema's van 'Quantification of HIV protease inhibitors and non-nucleoside reverse transcriptase inhibitors in peripheral blood mononuclear cell lysate using liquid chromatography coupled with tandem mass spectrometry'. Samen vormen ze een unieke vingerafdruk.

Citeer dit